Utility & Infra
Heijmans: 10kV installation assessed for risks
Power quality analysis of the Oosterschelde storm surge barrier, commissioned by Heijmans.
Faults and outages
Power QualityIdentifying and resolving the causes of faultsEMCIdentifying faults in control and communication systemsReliable installationDiagnosis of critical functions and wear and tearCapacity and grid congestion
Grid congestionFreeing up capacity within your connectionEnergy Management (EMS)Active management within your power limitsEnergy transitionIntegrating solar panels, charging points and heat pumpsNot quite sure what the issue is? An engineer will work with you to find a solution.
View all solutionsA project can begin with any one of these four.
View all servicesWe understand the risks and standards specific to each sector.
View all sectorsWe supply and commission filters, compensation systems and measuring equipment.
View all productsArticles, white papers, sessions and training courses delivered by our engineers.
Open the knowledge baseWe have been working in the fields of power quality, EMC and energy flows since 2007.
Read about HyTEPSFMCG
At Sappi Maastricht, the paper machine kept breaking down due to faulty control boards. The cause was the third harmonic. An active filter resolved the issue and paid for itself within a year.

Sappi Maastricht B.V. manufactures coated graphic paper. Downtime is costly there. Nevertheless, the analogue-to-digital cards in the process control system failed in quick succession, causing the paper machine to shut down repeatedly.
It was not immediately clear where the problem originated. HyTEPS was asked to identify the cause.
Our engineers carried out a comprehensive power quality measurement. This revealed that the installation was affected by harmonics; the third harmonic, in particular, was well above the applicable standards.
This harmonic distortion disrupted the sensitive process automation and caused components to fail prematurely. Without intervention, the paper machine would have continued to experience breakdowns.
HyTEPS installed an active filter that corrects harmonic currents in real time. Our engineers tuned the filter to the machine’s load.
The third harmonic has been reduced to virtually zero. Production downtime caused by these faults no longer occurs. Components last longer and energy consumption is lower. The filter paid for itself within a year.
One year after commissioning the HyTEPS active filter, we should note that a production downtime due to this process automation has not recurred. Add to this the increased component life and lower energy consumption, we can conclude that this filter has already paid for itself this year.
Utility & Infra
Power quality analysis of the Oosterschelde storm surge barrier, commissioned by Heijmans.
Healthcare
First, detailed measurements are taken, followed by continuous monitoring within the hospital.
Utility & Infra
EMC study for emergency services communications.
Industry
Specialist measurements at a zinc plant with currents of up to 77,000 A.
Utility & Infra
Tens of thousands of spectators rely on a system that operates without failure.
Industry
Harmonic distortion in the production of precision tubes.
Offshore
Years of cable insulation damage on the Bumblebee.
Utility & Infra
Precise measurements identified the risks associated with this critical installation.
Healthcare
Active harmonic filters in the hospital’s electrical installation.
You’ll receive a reply within one working day. Your first consultation will be with an engineer.