Industry
SNB: 1.75 MW reduction in grid load
High costs due to reactive power, despite on-site generation.
Faults and outages
Power QualityIdentifying and resolving the causes of faultsEMCIdentifying faults in control and communication systemsReliable installationDiagnosis of critical functions and wear and tearCapacity and grid congestion
Grid congestionFreeing up capacity within your connectionEnergy Management (EMS)Active management within your power limitsEnergy transitionIntegrating solar panels, charging points and heat pumpsNot quite sure what the issue is? An engineer will work with you to find a solution.
View all solutionsA project can begin with any one of these four.
View all servicesWe understand the risks and standards specific to each sector.
View all sectorsWe supply and commission filters, compensation systems and measuring equipment.
View all productsArticles, white papers, sessions and training courses delivered by our engineers.
Open the knowledge baseWe have been working in the fields of power quality, EMC and energy flows since 2007.
Read about HyTEPSIndustry
Grid congestion at North Sea Port was hampering OVET’s growth. HyTEPS installed metering equipment on all low-voltage installations. Using this data, OVET can identify where and when power is being drawn and implement peak shaving.

In the Zeeland section of North Sea Port, grid congestion is hampering the growth of large-scale consumers. OVET B.V. handles the transhipment and processing of dry bulk goods, with terminals in Vlissingen and Terneuzen. The electrification of cranes, the expansion of terminals and the provision of more robust shore power facilities were under pressure.
Consumption in Vlissingen came dangerously close to the connection capacity limit. The four floating cranes operate in island mode. During hoisting and lowering, significant fluctuations in voltage and harmonic distortion occur.
Our engineers installed measuring equipment on all low-voltage installations downstream of the high-voltage connection. Installations spread across the site are now continuously monitored. This makes it possible to see where and when power is being drawn.
The measurements revealed peaks and effects that had previously been invisible. When the IT department reported that a UPS had been triggered, the measurement data made it possible to quickly determine what had happened.
Using the Power Quality reports, OVET implemented an energy management system. Peaks and exceedances are now clearly visible, and the cause can be traced immediately. OVET applies peak shaving and, in consultation with other major consumers on site, prevents heavy-duty installations from switching on simultaneously.
OVET has been granted approval for a higher-capacity connection. The energy management system prevents the immediate need for a further increase in capacity thereafter. Disturbances caused by customers’ variable frequency drives are identified, allowing these to be addressed in good time.
OVET is investigating whether the energy released during the crane-raising celebrations can be reused, and also intends to introduce the monitoring system in Terneuzen.
Industry
High costs due to reactive power, despite on-site generation.
Industry
Measurements revealed unused reserve capacity; a battery system proved unnecessary.
FMCG
Energy insights and automatic HACCP recording in a single system.
Industry
No need for a higher-capacity grid connection to scale up production.
Utility & Infra
Active harmonic filters for installation in Hangar 14.
Industry
400 kVAr capacitor bank to counteract reactive power.
Industry
A new 5 MW installation was not to result in any outages.
Industry
Elimination of reactive power penalties and additional capacity with a 150 kVA capacitor bank.
Industry
Reactive power addressed using capacitor banks.
You’ll receive a reply within one working day. Your first consultation will be with an engineer.