Utility & Infra
ProfiNRG: EMC emissions from a mobile phone mast mapped
A new solar park next to a transmission mast had to meet strict EMC requirements.
Faults and outages
Power QualityIdentifying and resolving the causes of faultsEMCIdentifying faults in control and communication systemsReliable installationDiagnosis of critical functions and wear and tearCapacity and grid congestion
Grid congestionFreeing up capacity within your connectionEnergy Management (EMS)Active management within your power limitsEnergy transitionIntegrating solar panels, charging points and heat pumpsNot quite sure what the issue is? An engineer will work with you to find a solution.
View all solutionsA project can begin with any one of these four.
View all servicesWe understand the risks and standards specific to each sector.
View all sectorsWe supply and commission filters, compensation systems and measuring equipment.
View all productsArticles, white papers, sessions and training courses delivered by our engineers.
Open the knowledge baseWe have been working in the fields of power quality, EMC and energy flows since 2007.
Read about HyTEPSIndustry
At zinc producer Nyrstar in Budel, rectifiers were causing severe harmonic distortion. This led to malfunctions and faulty equipment. HyTEPS carried out measurements, modelling and recommended filters for the medium-voltage system.

Nyrstar Budel B.V. is the only zinc producer in the Netherlands and continuously produces 290,000 tonnes of zinc per year. Zinc ore is processed via electrolysis, with currents of up to 77,000 amperes per circuit.
To achieve this, the installation uses rectifiers. These are indispensable, but they are also the source of severe harmonic distortion. This distortion led to unexplained faults and equipment failures elsewhere in the grid.
Our engineers carried out measurements at strategic points within the installation. The power quality measurements provided insight into the harmonic currents and voltage distortion.
Simulations and a model were created using this data. This enabled the current situation to be assessed and the consequences of future scenarios to be predicted. The analysis is in line with IEC standards.
The recommendation was to connect the filters directly to the medium-voltage system. This tackles the interference at source, before it spreads through the rest of the installation. HyTEPS oversaw the project through to completion.
The result is a clean sine wave and a significantly lower risk of failure of key assets. The risk of premature component ageing and unexplained faults has also been reduced.
In the report, HyTEPS recommended compensating harmonic currents to us through Active Harmonic Filters because of the varying load. Connecting these to the medium voltage addresses the pollution at source.
Utility & Infra
A new solar park next to a transmission mast had to meet strict EMC requirements.
Healthcare
First, detailed measurements are taken, followed by continuous monitoring within the hospital.
Industry
Harmonic distortion in the production of precision tubes.
Industry
Sustainability measures have led to harmonic distortion and equipment failure.
Offshore
Years of cable insulation damage on the Bumblebee.
Healthcare
Active harmonic filters in the hospital’s electrical installation.
Utility & Infra
Power quality analysis of the Oosterschelde storm surge barrier, commissioned by Heijmans.
Utility & Infra
Harmonic distortion was threatening the security lanes.
Utility & Infra
EMC study for emergency services communications.
You’ll receive a reply within one working day. Your first consultation will be with an engineer.